1) Product Images from "The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty"
Article Title: The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty
Journal: Acta Orthopaedica
doi: 10.3109/17453674.2010.506632
Figure Legend Snippet: Polyethylene wear analysis with the PolyWare software. A. Circles are fitted to the peripheries of the cup and femoral head shadows B. At the end of the analysis a solid cup model is added to the output. Right hips are flipped about the vertical axis to look like left hips prior to analysis.
Techniques Used: Software
Figure Legend Snippet: Bland-Altman plots and scatter plots, with lines of equality for repeatability measures for each of the 3 methods. Bland-Altman plots (columns 1 and 3); x-axis: average of two measurements; y-axis: the difference between 2 measurements (y = measurement 1 – measurement 2); red lines: 95% limits of agreement; dashed line: bias from 0; solid green line: y = 0 line; dots: individual double measures. Scatter plots (columns 2 and 4); x-axis: first measurement; y-axis: second measurement; maroon lines: lines of equality; EGS-RSA: radiostereometric analysis using sphere models; PW1: PolyWare using only the final follow-up radiographs; PW2: PolyWare using the postoperative and final follow-up radiographs.
Techniques Used:
Figure Legend Snippet: Bland-Altman plots and scatter plots with lines of equality for concurrent validity between the 3 methods. Bland-Altman plots (columns 1 and 3); x-axis: average of the measurements of 2 methods; y-axis: difference between measurements of 2 methods; red lines: 95% limits of agreement; dashed line: bias from 0; solid green line: y = 0 line; dots: individual double measures. Scatter plots (columns 2 and 4); maroon lines: lines of equality; EGS-RSA: radiostereometric analysis using sphere models; PW1: PolyWare using only the final follow-up radiographs; PW2: PolyWare using the postoperative and final follow-up radiographs.
Techniques Used:
Figure Legend Snippet: Marginal cost analysis in € (euros) for polyethylene wear analysis by EGS-RSA and with PolyWare as used in this study. For easy comparison, the staff costs are listed per patient
Techniques Used: Comparison, Software